Honeywell Conventional Fire Alarm System

Pioneers in the industry, we offer system sensor multi sensor detector 2351tem, honeywell system sensor 2 zone panel ss/2ze, honeywell system sensor heat detector 5351/ec, honeywell system sensor hooter detector mhr/1, honeywell system sensor manual call point mcp2a and honeywell system sensor smoke detector -2351/ ec from India.

System Sensor Multi Sensor Detector 2351Tem

Request Callback

₹ 1150 / Piece Get Latest Price

Product Brochure
Body MaterialABS Plastic
Startup Time (sec)5 sec
Alarm Sensor TypePhotoelectric
Operating Voltage12v
Brand/CompanyHoneywell
Warranty1 year
ColorWhite

Minimum order quantity: 10 Piece

  • The 2351TEM photoelectric smoke/thermal detector forms part of the Series 300 range of conventional detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing conventional detector technology. With its multitude of innovative features, the Series 300 is a detector which ‘acts conventionally, thinks intelligently’. The 2351TEM photoelectric smoke/thermal detector incorporates an optical chamber and a thermal element, which in turn are continually monitored by an on board processor by using algorithms developed specifically for the unit. An alarm signal is only enabled in the detector once the processor is satisfied that an incipient fire has been detected. By using a combination of inputs, the incidence of nuisance alarms is reduced while at the same time, the response time to an actual fire is also improved.
FEATURES „ Low profile design „ Low current draw „ Backward compatible with Series 100 detector range of bases „ Wide operating voltage 8 to 30V „ Bi-colour LED detector status indicator „ Automatic drift compensation „ Programmable sensitivity „ Addressable feature „ Advanced maintenance features via remote hand-held test unit „ Range of detector bases available „ Approved to EN54–7:2000 EN54–5:2000 Class A1R; CEA4021 „ Extended warranty

Honeywell system sensor 2 zone panel SS/2ZE

Request Callback

₹ 10500 / Piece Get Latest Price

Product Brochure
Usage/ApplicationCommercial
Model Name/NumberSS/2ZEC
Voltage24V
Battery Type12v
Brandhoneywell
• Three Form-C relays (1 Fire, 1 Fault and 1 Fire/ Fault 2amps@30 VDC)
• 1 On-board NACs operating @ 0.5A/circuit
• Aux Output: 24VDC
• Sounder Output: 24VDC
• Feature Detection Circuits: 2 & 4 Zones (upto 20 Detectors + 5 MCPs)
• Zone wise Fire, Fault, Disable indication
• Panel keys: Silence Buzzer/Alarm; Reset; Navigation keys (Left, Right, Down, Menu/Ok)
• Lamp Test & Walk Test
• Standby power 24V DC (2 no’s of 12V, 7Ah Lead Acid Battery)
• Certification (CE, LVDE)
• Event Log- 1200 events
• Earth fault monitoring

Honeywell System Sensor Heat Detector 5351/EC

Request Callback

₹ 840 / Piece Get Latest Price

Product Brochure
Board TypeConventional
Startup Time (sec)10 sec
Operating Temperature-20 DegreeC to 60 DegreeC
Operating Voltage (VDC)12v
TypeConventional
System ComponentsHeat detector
Country of OriginMade in India
The 5351/E thermal detector forms part of the Series 300 range of conventional detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing conventional detector technology. The 5351/E thermal detector incorporates an Application Specific Integrated Circuit (ASIC). Combined with the latest in thermal element technology the detector provides efficient and accurate detection of fires, especially in environments such as bars or kitchens where smoke detectors are inappropriate due to the high level of airborne contamination. The 5351/E and other detectors in the Series 300 range are backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations.

Honeywell system sensor hooter detector MHR/1

Request Callback

₹ 850 / Piece Get Latest Price

Product Brochure
Usage/ApplicationOffices
MaterialPlastic
Power SourceAC Voltage
Siren Range110 dB
ColorRed
?es : Horn, Strobes & Horn Strobes Mounting plate included for compatibility with a wide range of ?back box sizes, ?Three field selectable candela settings: 15, 75, and 115, Easy to use rotary dials for selection of candela and horn ?settings, Built in synchronization feature keeps strobes in sync for up to ?30 minutes, ?Strobes Listed to UL1638; Horns Listed to UL464, Horn settings on the horn strobe model include high and low ?volume, continuous or temporal 3 tone, ?Round trim ring available for ceiling mount applications, ?Universal Fire symbol is language independent, Trim plate allows mini horn to mount to a variety of backboxes and fit aesthetically with the horn strobe and strobe. 

Honeywell System sensor manual call point MCP2A

Request Callback

₹ 840 / Piece Get Latest Price

Product Brochure
Usage/ApplicationFire Alarm System
Model Name/NumberMCP2A
Working Voltage24V
Relay OutputsTrouble Relay
ColorRED
Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the new MCP Indoor Call Point range. Installation time and ultimately cost, are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique ‘plug and play’ concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block, where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple, but effective with no re-termination required and no time wasted.

Honeywell system sensor smoke detector -2351/ EC

Request Callback

₹ 590 / Piece Get Latest Price

Product Brochure
Board TypeConventional
Alarm Sensor TypePhotoelectric
Product Typesmoke detector
Conventional Or Addressableconventional
Usage/ApplicationIndustrial Premises
Colorwhite
Automation GradeManual
Voltage12V
The 2351EC photoelectric smoke detector forms part of the Series 300 range of conventional detectors. This range of detectors has been produced using the latest in manufacturing and design techniques, pushing out the boundaries of existing conventional detector technology. Combined with the latest state of the art optical chamber the detector provides efficient and accurate detection of fires with a high level of resilience to nonfire environmental influences. The 2351EC detector is backward compatible with the Series 100 detector bases, thus providing the capability to upgrade, extend and maintain existing Series 100 installations. The 2351EC detector incorporates a bi-colour LED indicator. The integral LED changes colour according to the detector’s status - Green = Normal, Red = Alarm. This benefits the user by providing clear, instant visual indication of the detector’s condition. 

Honeywell /system sensor conventional 4 zone panel SS/4ZE

Request Callback

₹ 12500 / Piece Get Latest Price

Product Brochure
Usage/ApplicationCommercial
MaterialSheet Metal
Number of Zone8
Model Name/NumberSS/4ZEC
Voltage24V
BrandHoneywell

Minimum order quantity: 10 Piece

• Three Form-C relays (1 Fire, 1 Fault and 1 Fire/ Fault 2amps@30 VDC)
• 1 On-board NACs operating @ 0.5A/circuit
• Aux Output: 24VDC
• Sounder Output: 24VDC
• Feature Detection Circuits: 2 & 4 Zones (upto 20 Detectors + 5 MCPs)
• Zone wise Fire, Fault, Disable indication
• Panel keys: Silence Buzzer/Alarm; Reset; Navigation keys (Left, Right, Down, Menu/Ok)
• Lamp Test & Walk Test
• Standby power 24V DC (2 no’s of 12V, 7Ah Lead Acid Battery)
• Certification (CE, LVDE)
• Event Log- 1200 events
• Earth fault monitoring
X

Contact Us

Suhas Mangutkar (Director)
Accruepole Private Limited
0, Bhaweshwari Soc CTS 842 B, Singh Estate Samta Nagar, Kandivali
Kandivali East, Mumbai - 400101, Maharashtra, India

Get Directions
Send Email
Share: