Intrinsically Smoke Detector

Our range of products include jtygd2151eis photoelectric intrinsically safe smoke detectors, intrinsically safe conventional heat detector - hochiki - dcd-1e-is, intrinsically safe conventional smoke detector - hochiki - soc-e-is, dc9103 gst intrinsically heat detector and gst conventional dc-9101 intrinsically smoke detector.

JTYGD2151EIS Photoelectric Intrinsically Safe Smoke Detectors

Request Callback

₹ 5150 / Piece Get Latest Price

Product Brochure
Body MaterialABS Plastic
Alarm Sensor TypePhotoelectric
Operating Voltage32 VDC
Usage/ApplicationIndustrial Premises
ColorWhite
Automation GradeManual
Brand/CompanySystem Sensor
Voltage12V
Warranty1 year

Minimum order quantity: 100 Piece

  • Model JTY-GD-2151EIS is a conventional intrinsically safe photoelectric smoke detector uses state-of-the-art sensing chamber. The detector is designed to provide open area protection and is for use with 2-wire control panels via interface module. Each detector is equipped with two LEDs that provide a local, visual indication of detector status. Once the detector senses a fire, it latches on in alarm and remains the state until it is reset by a momentary power interruption. The detector can be tested by activating an internal reed switch with a test magnet. Model JTWB-BCD-5151EIS is a conventional 2- wire intrinsically safe thermal detector. This detector is designed to provide open area protection and is for use with 2-wire control panels via interface module. The detector utilizes a stateof-the-art thermistor sensing circuit for fast and accurate response. It can be used in various environmental conditions and also has the simple maintenance and lower fault rate advantages. Two red LEDs blink in standby status each 5S and latch on in alarm, and stop blinking in fault. A built-in test switch is designed for product testing. 

Intrinsically Safe Conventional Heat Detector - HOCHIKI - DCD-1E-IS

Request Callback

₹ 5750 / Piece Get Latest Price

Product Brochure
MaterialPlastic
Operating Temperature-10 DegreeC to 50 DegreeC
Model Name/NumberDCD-1E-IS
Operating Voltage (VDC)15 - 30 V dc
Weight (grams)97
  • Features 
  • Twin fire LEDs allow 360° viewing 
  • Electronics free mounting base Remote indicator output 
  • ATEX Classification to II 1G EEx ia IIC T5 Tamb=55 °C 
  • Suitable for installation in areas at Category 1 (inc all lower categories) 
  • Approved by LPCB and GL

Intrinsically Safe Conventional Smoke Detector - HOCHIKI - SOC-E-IS

Request Callback

₹ 5700 / Piece Get Latest Price

Product Brochure
TypeSmoke Detector
BrandHOCHIKI
ColorWHITE
Voltage12 - 30 VDC
Alarm Current40 mA
Operating Temp.-10 DegreeC to + 50 DegreeC
Humidity95% RH - Non condensing (at 40 DegreeC)
Size/Dimension106 * 100 * 48
Warranty1 YEAR
Model/TypeSOC-E-IS
  • Removable, High Performance chamber 
  • Automatic Sensitivity Window Verification (ASWV) – Drift Compensation Technology
  • Remote Indicator output 
  • Wide voltage range (5 ~ 30 VDC) 
  • Low profile design with one piece outer cover 
  • Single fire LED - 360° viewing 
  • ATEX Classification to: Ex ia IIC T5 Ga (-20°C ≤ Ta ≤ +55°C)
  • Suitable for installation in areas at Category 1 (inc all lower categories) 
  • Approved by LPCB & VdS

DC9103 GST Intrinsically Heat Detector

Request Callback

₹ 5150 / Piece Get Latest Price

Product Brochure
MaterialPlastic
Startup Time (sec)5 sec
Operating Voltage (VDC)12v
Automation GradeManual
Model Name/NumberDC-9103
Usage/ApplicationOffices
TypeConventional
System ComponentsHeat detector

Minimum order quantity: 10 Piece

Features

With novel structure, attractive appearance, stable and reliable performance, the detector is especially applicable to places where fire occurs with sharp rise of temperature. Used together with smoke detectors, it can detect fire with more reliability to reduce losses and chemical corrosion proof.

Description

DC-9103(IS) Intrinsically Safe Conventional Rate of Rise and Fixed Temperature Heat Detector is applicable to zone 1 and zone 2 of areas with explosion-proof requirement in petroleum, chemical industries and ships. Used together with I-9332 interface, it can be connected with compatible FACP (fire alarm control panel) to process fire alarm signals. The detector has two classes: A1R and BS. They can be set through an programmer on site.

GST Conventional DC-9101 Intrinsically Smoke Detector

Request Callback

₹ 5500 / Piece Get Latest Price

Product Brochure
TypeSmoke Detector
BrandGST
Materialplastic
Alarm Sensor TypePhotoelectric
Colorwhite
Automation GradeSemi-Automatic
Voltage12V

Minimum order quantity: 10 Piece

DC-9101 (IS) Intrinsically Safe Conventional Combination Heat Photoelectric Smoke Detector (the detector), non-addressable, is a kind of combination detector consisting of smoke sensing parts and semi-conductor heat sensing parts in technological structure and circuit structure. It’s applicable to zone 1 and zone 2 of areas with explosion-proof requirement in petroleum and chemical industries. It can match with fire alarm control panel, I-9332 Interface, explosion-proof detector and end-of-line resistor produced by GST to conduct the processing of detector signals. The detector has the advantages of both conventional photoelectric detector and rate of rise and fixed temperature heat detector. Just because of the combination of smoke detector and heat detector, it overcomes the non-sensitivity to dark smoke particles of ordinary scattering photoelectric detectors. It can also pick up fire with obvious rise of temperature such as alcohol flame, thus extending the application range. 
X

Contact Us

Suhas Mangutkar (Director)
Accruepole Private Limited
0, Bhaweshwari Soc CTS 842 B, Singh Estate Samta Nagar, Kandivali
Kandivali East, Mumbai - 400101, Maharashtra, India

Get Directions
Send Email
Share: