Ravel Conventional Fire Alarm System

Leading Wholesaler of ravel 2 zone conventional fire alarm panel -re-102, ravel conventional sounder cum strobe-re-25ss, re428hr ravel beam detector, fire control panel, re 316s2l-ul listed ravel convenitonal smoke detector and ravel 4 zone conventional fire alarm panel re-2554 from Mumbai.

Ravel 2 zone Conventional Fire Alarm panel -RE-102

Request Callback

₹ 3950 / Piece Get Latest Price

Product Brochure
Number of Zone2
Relay OutputsAlarm Relay
Model Name/NumberRE-102
Usage/ApplicationCommercial area
TypeConventional
System ComponentsFire Alarm Control Panel
Voltage24V DC
Country of OriginMade in India
As per IS -15908: 2011 Standard. ?16 X 2 Dot Matrix LCD Display. ?Standby battery backup with built in charging. ?Fire / Fault status in unambiguous colored LED indication. ?Switch Mode Power Supply. ?Tactile Keypad for easy panel operation. ?System ON indication. ?Main, Standby status indication. ?Low Battery visual warning with audible tone. ?Relay output for actuators, for Fire and Fault. ?Lamp Test facility. ?Zone wise one man Walk Test Facility. ?Zone wise Isolation facility with loop voltage cut off. ?Compatible to all type of Conventional Detectors. Optional Zone Wise Sounder / Zone Wise Contact

Ravel Conventional Sounder cum Strobe-RE-25SS

Request Callback

₹ 1150 / Piece Get Latest Price

Product Brochure
BrandRavel
MaterialPlastic
Body MaterialPlastic
ColorRED
Model Name/NumberRE-25SS
Operating Temperature-10 to 50 C
Input Voltage24V DC (15-30V)
RE-25SS sounder cum strobe are designed to simplify installations to provide primary and secondary for fire and security applications. These are ideal where smaller notifications devices is desired. The horns can be flush / ceiling mounted with / without back box. Strobe shall be wired as primary (or) secondary signaling notification appliance flashing at 1Hz over entire voltage operating range. Strobe light consists of Xenon flash tube. 

RE428HR Ravel Beam Detector

Request Callback

₹ 21400 / Piece Get Latest Price

Product Brochure
Range100 m
Alarm Sensor TypeOptical
Usage/ApplicationFire Safety
Operating Voltage24V
Operating Temperature-25 C to 55 C
BrandRavel
Dimension128 x 79 x 84 mm
Warranty1 year

Minimum order quantity: 10 Piece

  • User Friendly Installation 
  • In built laser light for easy alignment 
  • Supports 50 to100 meter range 
  • Option for Remote Indication
  • Adjusting Screws at detector for precise alignment 
  • Infrared transmitter & receiver located in a single housing 
  • In built drift compensation for monitoring dirt build up on the optical system Sensitivity Threshold :- 18% ,30%, 50%

Fire Control Panel

Request Callback

₹ 4500 / Piece Get Latest Price

Product Brochure
Number of Zone4
Usage/ApplicationCommercial
Body MaterialSheet Metal
Operating Temperature0 - 49 Degree C/32-120 Degree F.
Relative Humidity93 +- 2% RH (non- condensing) at 32 +-2 Degree C/90 +-3 Degree F.
Operating Current1.2A(Max)
FIRE ALARM CONTROL PANEL 

ravel fire alarm system ,
Microprocessor based conventional Fire Alarm Control Panel
This can be used as a standalone or networkable panel.

RE 316S2L-UL LISTED RAVEL CONVENITONAL SMOKE DETECTOR

Request Callback

₹ 650 / Piece Get Latest Price

Product Brochure
Alarm Sensor TypeOptical
BrandRAVEL
ColorWHITE
Weight130g with base
Operating Temp.-10 C to 37.8 C.
Operating Voltage9 ~ 33V DC
Humidity0 - 95% RH, non-condensing
No. Of Pieces1
IP Rating (Protection Rating)IP - 42
Warranty1 YEAR

Minimum order quantity: 1 Piece

  1.  UL listed. 
  2.  O Dual LED’s for 360 visibility. 
  3.  Advanced detection and communication protocol. 
  4.  Easy installation and maintenance. 
  5. Sleek low-profile housing design. 
  6.  Regular 100mm base. 

Ravel 4 Zone conventional Fire Alarm Panel RE-2554

Request Callback

₹ 8100 / Piece Get Latest Price

Product Brochure
BrandRavel
TypeConventional
Automation GradeManual
Battery Type12v
Wall MountedYes
Model Name/NumberRE - 2554
Usage/ApplicationCommercial area ,offices
System Componentsfikre alarm panel
Country of OriginMade in India
An automatic fire alarm system–typically made up of smoke detectors, heat detectors, manual Call Points, audible warning devices, and a fire alarm control with remote notification capability–can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire. The Manufacturer recommends that smoke and/or heat detectors be located throughout a protected premise following the recommendations of the current edition of the National Fire Protection Association Standard 72 (NFPA 72), manufacturer's recommendations, State and local codes, and the recommendations contained in the Guide for Proper Use of

Ravel 8 Zone conventional Fire Alarm Panel RE-2558

Request Callback

₹ 9650 / Piece Get Latest Price

Product Brochure
MaterialMild Steel (MS)
System ComponentsFire Alarm Control Panel
TypeConventional
BrandRavel
Usage/Applicationcommercial
Power SourceElectric
Relay OutputsAlarm Relay
Control KeysEvacuate
Switched Mode Power Supply.
Modular Construction ?Auto Resettable Fuse
Surge Protection for all Input and outputs.
Programmable AC loss delay/Trouble Remainder/Alarm Verification
Battery polarity reversible protection
Surface Mount Technolog

Ravel Conventional 4 Zone Gas Release panel RE-25AR

Request Callback

₹ 17100 / Piece Get Latest Price

Product Brochure
System ComponentsFire Alarm Control Panel
TypeConventional
Usage/Applicationcommercial
Model Name/NumberRE-25AR
Automation GradeManual
Country of OriginMade in India
An automatic fire alarm system–typically made up of smoke detectors, heat detectors, manual Call Points, audible warning devices, and a fire alarm control with remote notification capability–can provide early warning of a developing fire. Such a system, however, does not assure protection against property damage or loss of life resulting from a fire. The Manufacturer recommends that smoke and/or heat detectors be located throughout a protected premise following the recommendations of the current edition of the National Fire Protection Association Standard 72 (NFPA 72), manufacturer's recommendations, State and local codes, and the recommendations contained in the Guide for Proper Use of System Smoke Detectors, which is made available at no charge to all installing dealers. A study by the Federal Emergency Management Agency (an agency of the United States government) indicated that smoke detectors may not go off in as many as 35% of all fires. While fire alarm systems are designed to provide early warning against fire, they do not guarantee warning or protection against fire. A fire alarm system may not provide timely or adequate warning, or simply may not  

Ravel Manual Call Point RE- 716MR ( MCP )

Request Callback

₹ 360 / Piece Get Latest Price

Product Brochure
BrandRavel
System ComponentsManual Call Point
TypeConventional
Usage/ApplicationFire Alarm system
Body MaterialPlastic
ColorRed
Model Name/NumberRE- 716MR
Ravel Manual Call Point RE- 716MR
Fire Alarm Conventional Manual call Point

Operates on 24 VDC. ! Green Colored for Gas Release. ! Yellow Colored for Gas Abort. ! 1 No’s of CO & NC Output. A

Ravel Repeater Panel RE- 008RP

Request Callback

₹ 9650 / Piece Get Latest Price

Product Brochure
MaterialMild Steel (MS)
System ComponentsFire Alarm Control Panel
BrandRavel
Power SourceElectric
Model Name/NumberRE-008RP
ot Matrix LCD display.
Alphanumeric keypads.
RS 485 Communication for Network Repeater. System ON, AC ON, Battery ON, Charger ON indications.
Lamp test facility. Maximum 16 panels including repeater can be connected in a Single Network via RS-485.
Repeater Panel can monitor the status of RE-900 series panels via RS-485 Network communication.
User can Disable / Enable the Zone of Fire Alarm Control Panel Connected in network.

Ravel Conventional Photoelectric Smoke Detectors -RE-326-2SL

Request Callback

₹ 560 / Piece Get Latest Price

Product Brochure
Usage/ApplicationCommercial
BrandRAVEL
Voltage10 ~ 28V DC
FeaturesDual LED's for 360 visibility,Regular 100mm Base,EN-54 Standard
Alarm Current60 mA (Max.).
Weight130g with base
Operating Temp.0 C to 37.8 C.
Operating Voltage10 ~ 28V DC.
Dual LED’s for 360 visibility. Ÿ Advanced detection and communication protocol. Ÿ Easy installation and maintenance. Ÿ Sleek low -profile housing design. Ÿ Regular 100mm Base. Ÿ EN-54 Standard. Operating Voltage : 10 ~ 28V DC. O O Operating Temperature : 0 C to 37.8 C. Relative Humidity : 10% to 90% Reset Voltage : less than 1V. Stand by Current : 85 Micro Amps. Start Up Time : 30 Seconds. Cycle time : 28 - 35 Seconds. Alarm Current : 60 mA (Max.). Remote Output : 15mA maximum open collector. Smoke Sensitivity : 0.10 to 0.16 dB/m. O O Thermal Rating : 57 C(135 F). Alarm Contact Rating C,NO : 1A @ 30 VDC; 0.5A @ 125VAC. C,NC : 1A @ 30 VDC; 0.5A @ 125VAC (Optional On Order Basis)

Ravel Conventional Fire Alarm System-4 zone RE-104

Request Callback

₹ 5150 / Piece Get Latest Price

Product Brochure
System ComponentsFire Alarm Control Panel
TypeConventional
Usage/ApplicationCommercial area ,offices
Model Name/NumberRE-104
Voltage24V DC
Relay OutputsAlarm Relay
Control KeysEvacuate, Mute Buzzer, System Reset
Country of OriginMade in India
As per IS -15908: 2011 Standard. 16 X 2 Dot Matrix LCD Display. Standby battery backup with built in charging. Fire / Fault status in unambiguous colored LED indication.Switch Mode Power Supply.Tactile Keypad for easy panel operation.System ON indication.Main, Standby status indication.Low Battery visual warning with audible tone. Relay output for actuators, for Fire and Fault.Lamp Test facility Zone wise one man Walk Test Facility. Zone wise Isolation facility with loop voltage cut off.Compatible to all type of Conventional Detectors. Optional Zone Wise Sounder / Zone Wise Contact.

Ravel Conventional 2 Zone Gas Release panel RE-120GR

Request Callback

₹ 7950 / Piece Get Latest Price

Product Brochure
BrandRavel
Automation GradeManual
Model Name/NumberRE-120GR
Usage/Applicationcommercial
TypeConventional
System ComponentsFire Alarm Control Panel
Country of OriginMade in India
RE-120GR is a microprocessor based Agent Release Panel. These panel are a feature packed control unit performing dual function of detection and controlled release of gaseous agent. These panels have 2 detection circuits and 1 agent release circuit with various programmable options. The panel have all the safety features to prevent accidental release, easy to install, commission with user friendly programmable option, this panel is ideal choice to protect the premises

Ravel Fire Alarm Conventional Hooter RE- 24CS

Request Callback

₹ 425 / Piece Get Latest Price

Product Brochure
MaterialABS Plastic
Model Name/NumberRE-24CS
Usage/ApplicationFire Alarm system
TypeConventional
System ComponentsHooter
ColorRed
BrandRavel
Body MaterialPlastic
Ravel Fire Alarm Hooter RE- 24CS
Fire Alarm system
Fire Alarm Conventional Hooter
Sounders are designed to simplify installations to provide primary and secondary for fire and security applications

RE-120GR- Ravel gas Release Panel

Request Callback

₹ 7900 / Piece Get Latest Price

Product Brochure
TypeConventional Fire Alarm Systems
Usage/ApplicationCommercial
Model Name/NumberRAVEL-RE-120GR
IP RatingIP50
Power220-240 VAC, 10%, 50 Hz, 100W. Wire size: 1.5 Sq. mm with 600V insulation
Weight7 Kg
Warranty1 YEAR
Normal Operation Voltage24VDC, 300mA Max.
Operating Normal Voltage24 VDC
Dimensions (H x W x D)400W X 300H X 100D)
Ravel Indian Manufacturer, International standard. ? Modular Construction, Serviceable. ? Special logic circuitory to prevent accident release. ?Auto Resettable Fuse. ? Surge Protected. ? Battery polarity & deep discharge protection. ?Variable solenoid ON / OFF time. 2 No’s of programmable Initiating Device Circuit and 1 No. of Releasing Agent circuit.

Ravel Fire Alarm Control Panel RE-9020

Request Callback

₹ 15000 / Piece Get Latest Price

Product Brochure
Usage/ApplicationIndustrial
Model Name/NumberRE-9020
Voltage230v AC
Power24 v DC
Display TypeLCD
Weight10kg

Minimum order quantity: 1 Piece

* Complies with UL -864 and NFPA-72. * * Operates on 120 - 220v 60 /50 Hz, AC Mains power supply. * Standby (battery) backup 24v DC power supply with builtin charger. * Touch Keypad for user friendly operation. * Epoxy powder coated finish. * Class- B, Style B / C initiating device circuit (IDC). * All zones accept smoke detectors and any normally open contact device. * Class B Notification Appliance Circuits (NAC). * NAC shall be programmed as auto silence / Silence Inhibit. * Error free Fire / Fault status in unambiguous colored LED indication. * 1000 Event storage with RTC. * Main, Standby status with audible and visual indication. * Two Form C relays for fire and fault. * Resettable / Steady 24V D.C. Output. * RS 485 Communication facility. * TCP/IP facility (Optional) *MODBUS for BMS integration (Optional). * PC software (optional) * External Zone Wise Sounder/Contact via RS 485 (Optional). * All field wiring circuits are supervised. * Zone Isolation facility with loop voltage cut off. * Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. * Facility to connect Public Address System (PA) through RS-485 Communication.

RAVEL-Manual call point - RE-716MR

Request Callback

₹ 360 / Piece Get Latest Price

Product Brochure
BrandRavel
Usage/ApplicationFire Alarm System
Relay OutputsAlarm Relay
Model Name/NumberRE-716MR
Working Voltage24 VDC
Dimensions Mm86 X 86 X 50 mm
Box MaterialABS
ColorRed
Control KeysEvacuate, System Reset, Mute Buzzer
  • Red, Green, Yellow colour Plastic MCP’s.
  • Yellow and Green for Gas Abort & Release purpose.
  • 1 No’s of CO & NC Output.
  • Alarm status is indicated By Red colour LED.
  • Operates on 24 VDC.

Ravel 12 Zone Conventional Fire Alarm Panel RE-9012

Request Callback

₹ 11950 / Piece Get Latest Price

Product Brochure
MaterialMild Steel (MS)
System ComponentsFire Alarm Control Panel
TypeConventional
BrandRavel
Usage/Applicationcommercial
Power SourceElectric
Model Name/NumberRE-1092
Warranty1 year
Fully complies with UL -864 and NFPA-72. 
Rugged CRCA sheet with powder coated finish. Operates on 110 - 220v 50 /60 Hz, AC Mains power supply.
16x2 Dot Matrix LCD Display. 4/8 Class B Style ‘B ‘ or Style ’C’ 
initiating device circuit (IDC). 
All zones accept smoke detectors and any normally open contact device.
Any Zone can be configured as Alarm or supervisory Zone.
2 Class B Notification Appliance Circuits (NAC).  NAC shall be programmed as silenceable or Non Silenceable. 
Supervisory Zone shall be Latching or Resettable. 
Standby (battery) backup 24v DC power supply with built in charger 
Error free Fire / Fault status in unambiguous colored LED indication.
System ON indication.
Main, Standby status audible and visual indication.
Battery Low visual warning with audible tone. ? FormC relays for fire, fault and supervisory.
Resettable / Steady 24V D.C. Output. ? RS 485 Communication facility (Optional). 
Lamp Test facility. ? All field wiring circuits are Power limited except 110 - 220v AC and Battery.
All field wiring circuits are supervised. 
Walk Test facility.
Zone Isolation facility with loop voltage cut off. Earth fault annunciation facility at 0 ohms.
AC Low voltage cutoff.
Programmable AC loss delay. 
Programmable Alarm verification.
X

Contact Us

Suhas Mangutkar (Director)
Accruepole Private Limited
0, Bhaweshwari Soc CTS 842 B, Singh Estate Samta Nagar, Kandivali
Kandivali East, Mumbai - 400101, Maharashtra, India

Get Directions